DESCRIPTION:

Cogeneration plant ‘in island’ comprised by two HFO engines with heat recovery to produce thermic oil
destined to the laundry and DHW hotel demand. The plant counts with power generation with diesel engines as backup.

ELECTRICITY PRODUCTION

  • 2 x 1,700 kWe HFO engine generators Hyundai.
  • 3 x 1,000 kWe diesel engines generators.
  • 1 x 1,700 kWe diesel engines generator.
GENERACIÓN TOTAL ELECTRICIDAD: 8.100 kWe.

HEAT PRODUCTION

  • 2 x oil-water heat exchangers (140 °F).
  • 2 x recovery boilers for thermic oil (400 °F)
  • 2 x diesel boilers for thermic oil (400 °F).
GENERACIÓN TOTAL CALOR: 3.380 kWt.

COOLING PRODUCTION (42 °F)

  • 9 x water cooled screw chillers.
  • 2 x open circuit cooling towers
GENERACIÓN TOTAL FRÍO: 8.650 kWf.